The feasibility of fluorescent nano-particle for biological flow analysis in a microchannel
SCIE
SCOPUS
- Title
- The feasibility of fluorescent nano-particle for biological flow analysis in a microchannel
- Authors
- Park, CW; Kim, GM; Kim, DK; Lee, SJ
- Date Issued
- 2006-10-30
- Publisher
- WORLD SCIENTIFIC PUBL CO PTE LTD
- Abstract
- The biological flow characteristics inside a microchannel were investigated experimentally using a micro-particle image velocimetry (micro-PIV) method. The main objectives of this study were to understand the blood flow in micro-domain blood vessels and to identify the feasibility of nano-scale fluorescent particles for velocity measurement. The flow field was analyzed with a spatial resolution of 1Kx1K pixels at low Reynolds number flow. To obtain the spatial distributions of mean velocity, 100 instantaneous velocity fields were captured and ensemble-averaged. As a result, for the case of blood flow, there were substantial velocity variations in the central region of micro-channel due to the presence of blood cells in the blood flow.
- Keywords
- microchannel; micro-PIV; feasibility; fluorescent particle; blood flow
- URI
- https://oasis.postech.ac.kr/handle/2014.oak/23695
- DOI
- 10.1142/S0217979206041598
- ISSN
- 0217-9792
- Article Type
- Article
- Citation
- INTERNATIONAL JOURNAL OF MODERN PHYSICS B, vol. 20, no. 25-27, page. 4505 - 4510, 2006-10-30
- Files in This Item:
- There are no files associated with this item.