A theoretical model using a heat and mass transfer analogy and a simple model using Lee and Kim's [Lee, K.-Y., Kim, M.H., 2008a. Experimental and empirical study of steam condensation heat transfer with a noncondensable gas in a small-diameter vertical tube. Nucl. Eng. Des. 238, 207-216] correlation were developed to investigate steam condensation in the presence of a noncondensable gas inside a vertical tube Submerged in pool water. Rohsenow's correlation was used to consider the secondary pool-boiling heat transfer. Both models were assessed with the experimental data of Oh and Revankar [Oh, S., Revankar, S.T., 2005a. Investigation of the noncondensable effect and the operational modes of the passive condenser system. Nucl. Technol. 152, 71-86; Oh, S., Revankar, S.T., 2005b. Effect of noncondensable gas in a vertical tube condenser. Nucl. Eng. Des. 235, 1699-1712; Oh, S., Revankar, S.T., 2005c. Complete condensation in a vertical tube passive condenser. Int. Commun. Heat Mass Trans. 32, 593-602; Oh, S., Revankar, S.T., 2005d. Analysis of the complete condensation in a vertical tube passive condenser. Int. Commun. Heat Mass Trans. 32, 716-727; Ch, S., Revankar, S.T., 2006. Experimental and theoretical investigation of film condensation with noncondensable gas. Int. J. Heat Mass Trans. 49, 2523-2534; Oh, S., Gao, H., Revankar, S.T., 2007. Investigation of a passive condenser system of an advanced boiling water reactor. Nucl. Technol. 158, 208-218] for low pressure and Kim [Kim, S.J., 2000. Turbulent film condensation of high pressure steam in a vertical tube of passive secondary condensation system. Ph.D. dissertation, Korea Advanced institute of Science and Technology] for high pressure, which were obtained from in-tube steam condensation with air in the pool water. These models predicted the data of Oh and Revankar well, but they slightly underestimated the data of Kim. The design of the Passive Residual Heat Removal System (PRHRS) condensation heat exchanger was evaluated with the theoretical model at real operating conditions (e.g., secondary pool-boiling, high system pressure). The PRHRS condensation heat exchanger designed was estimated to remove sufficiently the remaining heat in a reactor during a major accident. (C) 2008 Elsevier BLV. All rights reserved.
Keywords
LAMINAR-FILM CONDENSATION; TUBE PASSIVE CONDENSER; VERTICAL TUBE; NONCONDENSABLE GAS; STEAM CONDENSATION; TURBULENT-FLOW; SYSTEM; MIXTURES; REACTOR
URI
https://oasis.postech.ac.kr/handle/2014.oak/22375
DOI
10.1016/j.nucengdes.2008.07.005
ISSN
0029-5493
Article Type
Article
Citation
NUCLEAR ENGINEERING AND DESIGN, vol. 238, no. 12, page. 3253 - 3262, 2008-12