Interlaboratory comparison of radiated emission measurements using a spherical dipole radiator
SCIE
SCOPUS
- Title
- Interlaboratory comparison of radiated emission measurements using a spherical dipole radiator
- Authors
- Kang, TW; Chung, YC; Won, SH; Kim, HT
- Date Issued
- 2001-01
- Publisher
- IEE-INST ELEC ENG
- Abstract
- An interlaboratory radiated emission comparison has been performed, comparing electric field strength measurements in the frequency range 30-1000MHz at a 10m open area test site. A spherical dipole radiator is employed as a reference emitter. Comparison results are presented in terms of measurement repeatability of electric field strengths measured at test sites for each frequency. Expanded uncertainty for the 95.45% confidence level is evaluated to be +5.61-5.7dB and +4.91-4.8dB for the frequency ranges corresponding to biconical and log-periodic antennas, respectively. Uncertainty analysis demonstrates that the uncertainty mainly stems from the antenna factor calibration, mismatch, the performance of a receiver and site imperfection.
- URI
- https://oasis.postech.ac.kr/handle/2014.oak/19656
- DOI
- 10.1049/ip-smt:20010184
- ISSN
- 1350-2344