Open Access System for Information Sharing

Login Library

 

Article
Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Cuffless Blood Pressure Estimation Model Using Clustering Techniques SCIE SCOPUS

Title
Cuffless Blood Pressure Estimation Model Using Clustering Techniques
Authors
Baek, JinHyeokLee, BongjinRachim, Vega PradanaJang, JaeseongKim, SangkyuKim, HeechanPark, Sung-Min
Date Issued
2023-10
Publisher
Institute of Electrical and Electronics Engineers
Abstract
This study introduces a clustered algorithm for estimating blood pressure (BP) using electrocardiographic and photoplethysmographic data obtained from 1675 subjects, corresponding to a total of 1051462 cardiac cycles. These data were sourced from the publicly accessible biosignal database, VitalDB. To enable the application of pulse wave analysis (PWA) on the recorded signals, the study extracted 29 morphological features from these signals and employed the K-means clustering algorithm to categorize them into six distinct clusters. Each of these clusters was used to train and optimize three separate BP estimation algorithms. Notably, the Shapley additive explanations analysis identified arterial stiffness and peripheral resistance as the most influential factors contributing to the clustering process. Experimental results reveal that the most accurate BP estimation model achieves deviations of 0.043 ± 6.43 mmHg for systolic BP and 0.052 ± 3.65 mmHg for diastolic BP. Remarkably, the adoption of clustering lead to notable enhancements in accuracy across key metrics, including mean error, standard deviation, and mean absolute error estimates. Importantly, these improvements align with the rigorous criteria established by three international BP standards: the Association for the Advancement of Medical Instrumentation/ISO, the British Hypertension Society, and the Institution of Electrical and Electronic Engineers. This study underscores the potential for clinical adoption of the clustering-based, cuffless BP estimation algorithm, which accommodates individual variations without necessitating a pretraining process for the subjects under investigation. IEEE
URI
https://oasis.postech.ac.kr/handle/2014.oak/120913
DOI
10.1109/jsen.2023.3327683
ISSN
1530-437X
Article Type
Article
Citation
IEEE Sensors Journal, page. 1 - 1, 2023-10
Files in This Item:
There are no files associated with this item.

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

박성민PARK, SUNG MIN
Dept. Convergence IT Engineering
Read more

Views & Downloads

Browse