Abstract
Bioresorbable vascular scaffold (BVS) has recently been spotlighted for its unique characteristics of absorbing into blood vessels and eventually disappearing. Although intravascular ultrasound (IVUS) is the most common guiding tool for stent deployment, the echogenicity of BVS struts has changed as the center of stent lumen and scanning rotation is not concentric, which may cause a critical erroneous measurement in practice. This study investigated the physical conditions for dimming the stent brightness in IVUS images using a finite-difference method (FDM) to numerically solve acoustic wave propagation through nonhomogeneous medium. The dimmed brightness is caused by an angled rectangular cross section of a strut and its similar acoustic impedance with water. Imaging frequency is not a major cause. However, the angle between the acoustic beam and the BVS surface is the major cause of the dimmed brightness. As a solution, an approach using a frequency compounding method with signal polarity comparator was proposed to recover the reduced brightness without sacrificing spatial resolutions. Based on the simulation study, the signal level from BVS can be attenuated down by 17 dB when the angle between the acoustic beamline and the surface of BVS is more than 45 degrees. With the proposed frequency compounding approach, the reduced signal can be recovered by 6 dB. In the experimental BVS IVUS imaging, strut brightness was reduced by 18 dB with an angled strut position and recovered by 5 dB with the proposed frequency compounding method. A pig coronary was imaged to demonstrate the performance of the proposed method.
URI
https://oasis.postech.ac.kr/handle/2014.oak/107489
DOI
10.1109/TUFFC.2020.2964322
ISSN
0885-3010
Article Type
Article
Citation
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, vol. 67, no. 6, page. 1090 - 1101, 2020-06
Files in This Item:
There are no files associated with this item.

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

장진아JANG, JIN AH
Dept of Mechanical Enginrg
Read more

Views & Downloads

Browse