Open Access System for Information Sharing

Login Library

 

Article
Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorKim, GB-
dc.contributor.authorLee, SJ-
dc.contributor.authorLee, JP-
dc.contributor.authorKim, JH-
dc.contributor.authorChang, SS-
dc.contributor.authorYoun, HS-
dc.contributor.authorSin, TJ-
dc.date.accessioned2016-04-01T01:31:42Z-
dc.date.available2016-04-01T01:31:42Z-
dc.date.created2009-08-25-
dc.date.issued2007-10-
dc.identifier.issn0374-4884-
dc.identifier.other2007-OAK-0000007222-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/23130-
dc.description.abstractThe majority of studies previously conducted on X-ray compound refractive lenses (CRLs) were related to synchrotron radiation (SR) facilities that had a relatively high photon energy level of several tens of keV. However, the performance of CRLs at an SR source with the main photon flux at a photon energy of 7 - 9 keV, such as that of the Pohang Light Source (PLS), is still not very apparent. In this present study; to find the effective experimental conditions for CRL applications at the PLS, we focused the SR beam by using a CRL fabricated with poly methyl methacrylate (PMMA) under a photon energy of 8 keV. Various CRLs with different configurations were fabricated using the LIGA (Lithographie, Galvanoformung, Abformtechnik) process, and the focused beam size was measured at the PLS by using two different experimental methods. The size of the measured focused beam was 7.2 mu m at a focal length of 298 mm. The CRLs developed in this study have a high potential and could eventually be used in real SR experiments at the PLS.-
dc.description.statementofresponsibilityX-
dc.languageEnglish-
dc.publisherKOREAN PHYSICAL SOC-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.subjectX-ray focusing-
dc.subjectparabolic CRL-
dc.subjectkinoform-
dc.subjectPMMA-
dc.subjectLIGA process-
dc.subjectLITHOGRAPHY-
dc.subjectOPTICS-
dc.titleFabrication of PMMA X-ray compound refractive lenses for the Pohang light source and performance tests-
dc.typeArticle-
dc.contributor.college기계공학과-
dc.identifier.doi10.3938/jkps.51.1256-
dc.author.googleKim, GB-
dc.author.googleLee, SJ-
dc.author.googleLee, JP-
dc.author.googleKim, JH-
dc.author.googleChang, SS-
dc.author.googleYoun, HS-
dc.author.googleSin, TJ-
dc.relation.volume51-
dc.relation.issue4-
dc.relation.startpage1256-
dc.relation.lastpage1262-
dc.contributor.id10054593-
dc.relation.journalJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.relation.indexSCI급, SCOPUS 등재논문-
dc.relation.sciSCI-
dc.collections.nameJournal Papers-
dc.type.rimsART-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.51, no.4, pp.1256 - 1262-
dc.identifier.wosid000250176700003-
dc.date.tcdate2019-01-01-
dc.citation.endPage1262-
dc.citation.number4-
dc.citation.startPage1256-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume51-
dc.contributor.affiliatedAuthorLee, SJ-
dc.identifier.scopusid2-s2.0-35648973124-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.wostc2-
dc.type.docTypeArticle-
dc.subject.keywordAuthorX-ray focusing-
dc.subject.keywordAuthorparabolic CRL-
dc.subject.keywordAuthorkinoform-
dc.subject.keywordAuthorPMMA-
dc.subject.keywordAuthorLIGA process-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

이상준LEE, SANG JOON
Dept of Mechanical Enginrg
Read more

Views & Downloads

Browse