DC Field | Value | Language |
---|---|---|
dc.contributor.author | Moon, IK | - |
dc.contributor.author | Jung, DH | - |
dc.contributor.author | Lee, KB | - |
dc.contributor.author | Jeong, YH | - |
dc.date.accessioned | 2016-03-31T13:32:18Z | - |
dc.date.available | 2016-03-31T13:32:18Z | - |
dc.date.created | 2009-02-28 | - |
dc.date.issued | 2000-04-24 | - |
dc.identifier.issn | 0003-6951 | - |
dc.identifier.other | 2000-OAK-0000001260 | - |
dc.identifier.uri | https://oasis.postech.ac.kr/handle/2014.oak/20049 | - |
dc.description.abstract | We developed an ac microcalorimeter utilizing the Peltier effect of a thermocouple junction as an ac power source. This Peltier microcalorimeter allows us to measure the absolute value of the heat capacity of small samples with submilligrams of mass. The performance of the microcalorimeter was checked in the temperature range of 15-420 K with alpha-Al2O3 samples of 0.54 and 2.25 mg. The absolute accuracy was +/- 3% for the range of 30-150 K and +/- 1% for 150-420 K. The precision was better than 0.5% in the whole temperature range. (C) 2000 American Institute of Physics. [S0003-6951(00)03917-6]. | - |
dc.description.statementofresponsibility | X | - |
dc.language | English | - |
dc.publisher | AMER INST PHYSICS | - |
dc.relation.isPartOf | APPLIED PHYSICS LETTERS | - |
dc.title | Peltier microcalorimeter | - |
dc.type | Article | - |
dc.contributor.college | 물리학과 | - |
dc.identifier.doi | 10.1063/1.126373 | - |
dc.author.google | Moon, IK | - |
dc.author.google | Jung, DH | - |
dc.author.google | Lee, KB | - |
dc.author.google | Jeong, YH | - |
dc.relation.volume | 76 | - |
dc.relation.issue | 17 | - |
dc.relation.startpage | 2451 | - |
dc.relation.lastpage | 2453 | - |
dc.contributor.id | 10052251 | - |
dc.relation.journal | APPLIED PHYSICS LETTERS | - |
dc.relation.index | SCI급, SCOPUS 등재논문 | - |
dc.relation.sci | SCI | - |
dc.collections.name | Journal Papers | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | APPLIED PHYSICS LETTERS, v.76, no.17, pp.2451 - 2453 | - |
dc.identifier.wosid | 000086538700043 | - |
dc.date.tcdate | 2019-01-01 | - |
dc.citation.endPage | 2453 | - |
dc.citation.number | 17 | - |
dc.citation.startPage | 2451 | - |
dc.citation.title | APPLIED PHYSICS LETTERS | - |
dc.citation.volume | 76 | - |
dc.contributor.affiliatedAuthor | Lee, KB | - |
dc.contributor.affiliatedAuthor | Jeong, YH | - |
dc.identifier.scopusid | 2-s2.0-0001378451 | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.wostc | 10 | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | THERMAL-CONDUCTIVITY | - |
dc.subject.keywordPlus | SENSOR | - |
dc.subject.keywordPlus | HEAT | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Physics | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
library@postech.ac.kr Tel: 054-279-2548
Copyrights © by 2017 Pohang University of Science ad Technology All right reserved.