Open Access System for Information Sharing

Login Library

 

Article
Cited 17 time in webofscience Cited 18 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
DC FieldValueLanguage
dc.contributor.authorHwang, I-
dc.contributor.authorHUANG, JUNG YUN-
dc.contributor.authorKim, M-
dc.contributor.authorLee, BJ-
dc.contributor.authorKim, C-
dc.contributor.authorChoi, JY-
dc.contributor.authorKim, MH-
dc.contributor.authorLee, HS-
dc.contributor.authorMoon, D-
dc.contributor.authorLee, EH-
dc.contributor.authorKim, DE-
dc.contributor.authorNam, SH-
dc.contributor.authorShin, S-
dc.contributor.authorCho, M-
dc.date.accessioned2015-06-25T03:31:12Z-
dc.date.available2015-06-25T03:31:12Z-
dc.date.created2014-09-16-
dc.date.issued2014-05-
dc.identifier.issn0034-6748-
dc.identifier.other2015-OAK-0000030245en_US
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/12833-
dc.description.abstractAfter three years of upgrading work, PLS-II (S. Shin, Commissioning of the PLS-II, JINST, January 2013) is now successfully operating. The top-up operation of the 3 GeV linear accelerator had to be delayed because of some challenges encountered, and PLS-II was run in decay mode at the beginning in March 2012. The main difficulties encountered in the top-up operation of PLS-II are different levels between the linear accelerator and the storage ring, the 14 narrow gap in-vacuum undulators in operation, and the full energy injection by 3 GeV linear accelerator. Large vertical emittance and energy jitter of the linac were the major obstacles that called for careful control of injected beam to reduce beam loss in the storage ring during injection. The following measures were taken to resolve these problems: (1) The high resolution Libera BPM (see http://www.i-tech.si) was implemented to measure the beam trajectory and energy. (2) Three slit systems were installed to filter the beam edge. (3) De-Qing circuit was applied to the modulator system to improve the energy stability of injected beam. As a result, the radiation by beam loss during injection is reduced drastically, and the top-up mode has been successfully operating since 19th March 2013. In this paper, we describe the experimental results of the PLS-II top-up operation and the improvement plan. (C) 2014 AIP Publishing LLC.-
dc.description.statementofresponsibilityopenen_US
dc.languageEnglish-
dc.publisherAIP-
dc.relation.isPartOfREVIEW OF SCIENTIFIC INSTRUMENTS-
dc.rightsBY_NC_NDen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.0/kren_US
dc.titleTop-up operation at Pohang Light Source-II-
dc.typeArticle-
dc.contributor.college첨단원자력공학부en_US
dc.identifier.doi10.1063/1.4878256-
dc.author.googleHwang, Ien_US
dc.author.googleHuang, JYen_US
dc.author.googleCho, Men_US
dc.author.googleShin, Sen_US
dc.author.googleNam, SHen_US
dc.author.googleKim, DEen_US
dc.author.googleLee, EHen_US
dc.author.googleMoon, Den_US
dc.author.googleLee, HSen_US
dc.author.googleKim, MHen_US
dc.author.googleChoi, JYen_US
dc.author.googleKim, Cen_US
dc.author.googleLee, BJen_US
dc.author.googleKim, Men_US
dc.relation.volume85en_US
dc.relation.issue5en_US
dc.relation.startpage55113en_US
dc.relation.lastpage055113-10en_US
dc.contributor.id10151947en_US
dc.relation.journalREVIEW OF SCIENTIFIC INSTRUMENTSen_US
dc.relation.indexSCI급, SCOPUS 등재논문en_US
dc.relation.sciSCIen_US
dc.collections.nameJournal Papersen_US
dc.type.rimsART-
dc.identifier.bibliographicCitationREVIEW OF SCIENTIFIC INSTRUMENTS, v.85, no.5, pp.55113 - 55113-10-
dc.identifier.wosid000337104600075-
dc.date.tcdate2019-01-01-
dc.citation.endPage55113-10-
dc.citation.number5-
dc.citation.startPage55113-
dc.citation.titleREVIEW OF SCIENTIFIC INSTRUMENTS-
dc.citation.volume85-
dc.contributor.affiliatedAuthorHUANG, JUNG YUN-
dc.contributor.affiliatedAuthorCho, M-
dc.identifier.scopusid2-s2.0-84901361433-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.wostc10-
dc.description.scptc11*
dc.date.scptcdate2018-10-274*
dc.type.docTypeArticle-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaPhysics-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

조무현CHO, MOO HYUN
Div. of Advanced Nuclear Enginrg
Read more

Views & Downloads

Browse