<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-26T13:24:41Z</responseDate><request verb="GetRecord" identifier="oai:oasis.postech.ac.kr:2014.oak/1969" metadataPrefix="mets">https://oasis.postech.ac.kr/oai/request</request><GetRecord><record><header><identifier>oai:oasis.postech.ac.kr:2014.oak/1969</identifier><datestamp>2021-11-24T13:23:14Z</datestamp><setSpec>com_2014.oak_418</setSpec><setSpec>col_2014.oak_422</setSpec></header><metadata><mets xmlns="http://www.loc.gov/METS/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd" PROFILE="DSpace METS SIP Profile 1.0" TYPE="DSpace ITEM" ID="&#xa;&#x9;&#x9;&#x9;&#x9;DSpace_ITEM_2014.oak-1969" OBJID="&#xa;&#x9;&#x9;&#x9;&#x9;hdl:2014.oak/1969">
<metsHdr CREATEDATE="2026-11-26T22:24:41Z">
<agent TYPE="ORGANIZATION" ROLE="CUSTODIAN">
<name>OASIS Repository @POSTECHLIBRARY</name>
</agent>
</metsHdr>
<dmdSec ID="DMD_2014.oak_1969">
<mdWrap MDTYPE="MODS">
<xmlData xmlns:mods="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:mods xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>Taiuk Rim</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">college</mods:roleTerm>
</mods:role>
<mods:namePart>일반대학원 전자전기공학과</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">department</mods:roleTerm>
</mods:role>
<mods:namePart>Department of Electrical Engineering (Semiconductor Program)</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2014-12-01T11:48:52Z</mods:dateAccessioned>
</mods:extension>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2014-12-01T11:48:52Z</mods:dateAvailable>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2013</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="other">OAK-2014-01467</mods:identifier>
<mods:identifier type="uri">http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001623259</mods:identifier>
<mods:abstract>The biologically sensitive field-effect transistor (BioFET) is the most promising sensor for ubiquitous healthcare applications due to its advantages such as small size, low power consumption, high-speed response, label-free detection, high sensitivity, high stability, and suitability for mass-production and integration with other electronic systems. Recently, nanowires (NWs) have been used for the channel region of the devices due to the enhanced gate controllability and size compatibility to that of biological molecules for cell and protein studies.    In this study, a honeycomb nanowire (HCNW) structure is proposed for highly sensitive BioFETs due to many structural benefits. The HCNW is a structure with repetitive hexagonal nanowire blocks. It has remarkable advantages in three aspects such as structural stability, surface area, and self-optimized current path. First, the HCNW shows superior structural stability due to its outstanding capability in force transferring. Therefore, we are able to fabricate the suspended nanowire structure without additional fabrication techniques and to make the fabrication process free from the stiction problem. Second, the surface area of the HCNWs is higher than that of the conventional straight-line nanowires (SLNWs). Hence, the effective width of the device is increased and the sensitivity in the strong inversion regime is enhanced. Finally, the self-optimized current path enhances the current drivability of the devices as well and suppresses statistical device-to-device variation statistically.   For a fair comparison of electrical characteristics between the HCNW and the SLNW BioFETs, both devices were fabricated on the same wafer with a distance of 300 microns. The HCNW BioFETs clearly show enhanced electrical characteristics such as lower threshold voltage, lower subthreshold swing, and higher drain current in the same gate overdrive voltage than those of the SLNW devices. Improved electrical characteristics mainly come from geometrical benefits of the HCNW such as the increased effective width and optimal current path. As a result, these notable characteristics of the HCNW enable higher sensitivity in all operation regimes, caused by lower subthreshold swing in the subthreshold regime and higher transconductance in the strong inversion regime. The above results show that the HCNW structure is very promising for enhancing the device performance and for realizing highly sensitive biosensors.   For miniaturization for hand-held applications, an Ag/AgCl pseudo-reference electrode (pRE) was embedded on the wafer. The pREs were fabricated using a combination of conventional microfabrication technique and electrochemical reaction with optimization. The open-circuit potential (OCP) characteristics between the pRE and a commercial reference electrode have been measured in order to evaluate the influence of the pRE potential on the device performance. The embedded pRE shows stable voltage drivability and the potential was insensitive to the hydrogen ion concentration and biological molecule concentration with offset of 6 mV and 1.5 mV for pH and alpha fetoprotein concentration, respectively. Those characteristics are critical for the reference electrodes of biosensors.</mods:abstract>
<mods:language>
<mods:languageTerm authority="rfc3066" />
</mods:language>
<mods:accessCondition type="useAndReproduction">BY_NC_ND</mods:accessCondition>
<mods:titleInfo>
<mods:title>A Study on Highly Sensitive BioFETs based on Honeycomb Nanowires</mods:title>
</mods:titleInfo>
<mods:genre>Thesis</mods:genre>
</mods:mods>
</xmlData>
</mdWrap>
</dmdSec>
<structMap TYPE="LOGICAL" LABEL="DSpace Object">
<div TYPE="DSpace Object Contents" ADMID="DMD_2014.oak_1969" />
</structMap>
</mets>
</metadata></record></GetRecord></OAI-PMH>