<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-26T13:00:57Z</responseDate><request verb="GetRecord" identifier="oai:oasis.postech.ac.kr:2014.oak/1267" metadataPrefix="mets">https://oasis.postech.ac.kr/oai/request</request><GetRecord><record><header><identifier>oai:oasis.postech.ac.kr:2014.oak/1267</identifier><datestamp>2021-11-24T13:21:37Z</datestamp><setSpec>com_2014.oak_408</setSpec><setSpec>col_2014.oak_411</setSpec></header><metadata><mets xmlns="http://www.loc.gov/METS/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd" PROFILE="DSpace METS SIP Profile 1.0" TYPE="DSpace ITEM" ID="&#xa;&#x9;&#x9;&#x9;&#x9;DSpace_ITEM_2014.oak-1267" OBJID="&#xa;&#x9;&#x9;&#x9;&#x9;hdl:2014.oak/1267">
<metsHdr CREATEDATE="2026-11-26T22:00:57Z">
<agent TYPE="ORGANIZATION" ROLE="CUSTODIAN">
<name>OASIS Repository @POSTECHLIBRARY</name>
</agent>
</metsHdr>
<dmdSec ID="DMD_2014.oak_1267">
<mdWrap MDTYPE="MODS">
<xmlData xmlns:mods="http://www.loc.gov/mods/v3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:mods xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:role>
<mods:roleTerm type="text">author</mods:roleTerm>
</mods:role>
<mods:namePart>조종윤</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">college</mods:roleTerm>
</mods:role>
<mods:namePart>일반대학원 기계공학과</mods:namePart>
</mods:name>
<mods:name>
<mods:role>
<mods:roleTerm type="text">department</mods:roleTerm>
</mods:role>
<mods:namePart>POSTECH</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2014-12-01T11:47:36Z</mods:dateAccessioned>
</mods:extension>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2014-12-01T11:47:36Z</mods:dateAvailable>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2011</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="other">OAK-2014-00765</mods:identifier>
<mods:identifier type="uri">http://postech.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001097828</mods:identifier>
<mods:abstract>In this master thesis, a micro-chamber system is studied and developed to enhance of measurement reliability using PEMC(PiezoElectric Micro-Cantilever) sensor in order to use in a portable diagnosis system or Lab-On-a-Chip(LOC) for detecting biomaterials such as protein or DNA.The PEMS sensor has been developed for mass sensor by our group. The sensor detects a tiny amount of mass the change in the resonance frequency of a micro-cantilever with a piezoelectric film based on the mass-micro-balancing technique.In order to measure accurate a tiny amount of mass, the environmental effects such as air condition, humidity and temperature are considered. The method to determine the PEMC sensor is actuated in micro-chamber to minimize the environmental effects and use array PEMC sensor for multi-plexed detection.The shape, size and PEMC position in chamber are consided in micro-chamber design because its acoustic-structure interaction effect is very high due to the large acoustic radiation impedance in micro-chamber.A numerical approach to investigate the size and shape effect on the resonance frequency and sensitivity associated with the first mode of micro-cantilever vibration in micro-chamber.The numerical simulation results using COMSOL are verified by experiments and compared with the approximate analytical solutions.And an array PEMC sensor is tested by detecting HBsAg in micro-chamber using “flow and dry technique”. The results of the HBsAg detection experiments show that the performance of the sensor is analyzed in micro-chamber.</mods:abstract>
<mods:language>
<mods:languageTerm authority="rfc3066" />
</mods:language>
<mods:accessCondition type="useAndReproduction">BY_NC_ND</mods:accessCondition>
<mods:titleInfo>
<mods:title>마이크로 챔버 내에서의 압전 캔틸레버 센서의 측정 신뢰성 확보 기술</mods:title>